Description

Permabond TA4810 is a two-part, 1:1 toughened acrylic adhesive (methyl methacrylate) for structural bonding of thermoplastics, thermosets, metals, and composites. It forms high-strength bonds to as-received metal, and Permabond lists it for plastics and unprimed metals. Surfaces still need to be clean, dry, and grease-free. The thixotropic paste dispenses through a static mixer with good gap filling and non-sag behavior. Structural acrylic bonding is a short routine: degrease, apply a thin bead through the mixer, close the joint inside the pot life, and hold pressure until the part reaches handling strength.

Key Product Details

Property Value
Chemistry Two-part toughened methyl methacrylate (MMA) acrylic. Part A and Part B are both methyl methacrylate based
Mix ratio 1:1
Color Part A off-white, Part B amber, mixed cream
Viscosity at 25°C (77°F) Part A 150,000 to 230,000 mPa.s (cP), Part B 120,000 to 200,000 mPa.s (cP)
Specific gravity 1.0 (Part A and Part B)
Maximum gap fill 2 mm (0.08 in)
Shear strength, steel (ISO 4587) 21 to 28 N/mm² (3,000 to 4,000 psi)
Shear strength, aluminum (ISO 4587) 14 to 22 N/mm² (2,000 to 3,200 psi)
Shear strength, fiberglass to fiberglass Greater than 12 N/mm² (1,700 psi)
PPO to HIPS, PVC to PVC, SMC to SMC Substrate failure
Tensile strength (ISO 37) 29 N/mm² (4,200 psi)
Peel strength (ISO 4578) 70 to 90 N/25 mm (15 to 20 PIW)
Elongation (ISO 37) 15 to 20%
Coefficient of thermal expansion (ASTM D-696) 80 x 10-6 1/K
Thermal conductivity (ASTM C-177) 0.1 W/(m.K)
Dielectric strength (ASTM D-149) 30 to 50 kV/mm
Volume resistivity (ASTM D-257) 2 x 1013 Ohm.cm
Service temperature -40°C to 120°C (-40°F to 250°F)
Storage temperature 2°C to 25°C (35°F to 77°F)
Available sizes 50ml cartridge, 400ml cartridge

Strength results vary with surface preparation and gap.

Cure Schedule at 23°C (73°F)

Stage Time
Pot life (10 g + 10 g) 4 to 6 minutes
Fixture time 10 to 15 minutes
Handling time (0.3 N/mm² shear strength) 20 to 30 minutes
Working strength 50 to 60 minutes
Full cure 24 hours

Curing at higher or lower temperatures changes cure speed. Source: Permabond TA4810 Technical Data Sheet (PDF), Global TDS Revision 3, 23 February 2018.

Performance in Production

  • Fixture time of 10 to 15 minutes and handling time of 20 to 30 minutes at 23°C (73°F) let you clamp a part, then move it along once it reaches handling strength.
  • Pot life is 4 to 6 minutes on a 10 g plus 10 g mix, so dispense through the static mixer and close the joint right away.
  • The thixotropic, non-sag paste holds a bead in place after dispensing and fills gaps up to 2 mm (0.08 in). Wider gaps need a shim or a redesigned joint.
  • Steel shear strength of 21 to 28 N/mm² and aluminum shear strength of 14 to 22 N/mm² on as-received metal support structural joints without a separate primer step.
  • On PPO to HIPS, PVC to PVC, and SMC to SMC test joints, the plastic failed before the bond line did.
  • Peel strength of 70 to 90 N/25 mm and 15 to 20% elongation give the cured bond some flex under peel and impact loads.
  • Resists many common industrial solvents and fuels. Not recommended for contact with strong oxidizing materials, and it may affect some thermoplastics, so test your plastic first.

Common Applications

  • Structural bonding of plastics and unprimed metals
  • Bonding thermoplastics, thermosets, and composites
  • Steel and aluminum assemblies bonded on as-received metal
  • Fiberglass-to-fiberglass bonding
  • Plastic joints on PPO, HIPS, PVC, and SMC
  • Assemblies that see brief high-temperature exposure such as paint baking or wave soldering, where the joint is not unduly stressed

Available Sizes

Size SKU Manufacturer Part Number
50ml Cartridge PERTA04810K050C1607 TA04810K050C1607
400ml Cartridge PERTA04810K400C1607 TA04810K400C1607

Mixers and Dispensing Guns

Cartridge Type Part Details
50ml Static mixer PERDD50MLSTATICMIXER02 (MAQ 05-16L) Quadro, 16 elements
50ml Static mixer, longer CON-MAQ-05-24L (MAQ 05-24L) Quadro, 24 elements, 5.3 mm (0.21 in) ID, 115 mm (4.5 in) long
50ml Static mixer, Nordson TAH190-620 20 elements, 0.250 in diameter, 5.9 in long, slip luer outlet
50ml Manual gun CCH50G-1-1/2-1 Chem-Set Pak-50, 1:1 and 2:1 plunger
50ml Manual gun PERDD50MLCOMBOGUN 50ml combo gun, 1:1 and 2:1 (Sulzer DMA 51-00-10)
50ml Pneumatic gun COX-DP2C050-01-110-111 AirFlow 1 CBA 25 R50, 50ml 1:1
400ml Static mixer TAH180AN-824 Nordson 180AN-824 (7701385), turbo mixer, integral nut, stepped outlet, 24 elements, 0.344 in (8.7 mm) ID, 6.8 in long
400ml Manual gun ALB-B26T400 Albion B26T400, 1:1 and 2:1, for 380ml, 395ml, and 400ml cartridges
400ml Manual gun CON-DM2X400-01-60-01 Sulzer Medmix DM2X 400-01-60-01, 400ml, 1:1 and 2:1

The 180AN-824 carries its own nut, so the cartridge thread has to match the mixer.

Related Products

How Structural Acrylic Bonding Works

Structural acrylic bonding joins plastics, metals, and composites with a two-part methacrylate that cures at room temperature. The steps below follow the TA4810 data sheet.

  1. Clean and degrease both surfaces. They must be clean, dry, and grease-free. Permabond Cleaner A is recommended for degreasing most surfaces.
  2. Abrade aluminum, copper, and their alloys lightly with emery cloth or similar to remove the oxide layer.
  3. Dispense the adhesive through a static mixer and apply a thin bead.
  4. Assemble the components and clamp them inside the pot life.
  5. Maintain pressure until handling strength is reached. The time varies with joint design and the surfaces being bonded.
  6. Allow 24 hours for full cure.

TA4810 test data covers steel, aluminum, fiberglass, PPO to HIPS, PVC, and SMC. Check any other plastic for compatibility before production.

Frequently Asked Questions

What is Permabond TA4810 used for?

Permabond TA4810 is used for structural bonding of plastics, composites, and metals, including steel and aluminum. It is a two-part, 1:1 toughened acrylic adhesive that dispenses through a static mixer, fills small gaps, and comes in 50ml and 400ml cartridges.

Is TA4810 an acrylic, a methacrylate, or an MMA adhesive?

All three terms describe the same chemistry. TA4810 is a toughened methyl methacrylate (MMA) adhesive, sold as a toughened acrylic, a toughened methacrylate, and a structural acrylic. Part A and Part B are both methyl methacrylate based.

How long does TA4810 take to cure?

Full cure takes 24 hours at 23°C (73°F). The cure schedule above gives pot life, fixture time, handling time, and working strength. Cure speed changes with temperature, so test at your shop temperature.

Do I need a primer to bond metal with TA4810?

Permabond lists TA4810 for unprimed metals, and the data sheet reports adhesion to as-received metal surfaces. The surface still has to be clean, dry, and grease-free, and aluminum, copper, and their alloys benefit from light abrasion to remove the oxide layer.

Will TA4810 bond plastic?

TA4810 is designed for bonding thermoplastics and thermosets. In Permabond test joints, PPO to HIPS, PVC to PVC, and SMC to SMC failed in the substrate and not at the bond line. The data sheet also warns that TA4810 may affect some thermoplastics, so test compatibility on your plastic. Call us with your resin and we will help check fit.

What mixer and gun do I use with TA4810?

For the 50ml cartridge, use the MAQ 05-16L static mixer, PERDD50MLSTATICMIXER02, or the longer 24-element MAQ 05-24L, CON-MAQ-05-24L, with a 1:1 50ml gun such as the CCH50G-1-1/2-1. For the 400ml cartridge, use the Nordson 180AN-824 mixer, TAH180AN-824, with a 400ml 1:1 manual gun such as the ALB-B26T400 or the CON-DM2X400-01-60-01. The Mixers and Dispensing Guns table above lists the full set.

What temperature range can TA4810 handle?

Permabond lists service temperature at -40°C to 120°C (-40°F to 250°F). The data sheet says the cured adhesive can withstand higher temperatures for brief periods, such as paint baking and wave soldering, as long as the joint is not unduly stressed. Strength retention falls as temperature rises, so check the Hot Strength curve in the data sheet for your temperature.

What is the difference between TA4810 and TA4820?

TA4820 is the longer-working-time grade. Permabond’s structural acrylic selection guide lists TA4820 with a 30 to 35 minute fixture time and a 100 to 120 minute working strength time, compared with 10 to 15 minutes and 50 to 60 minutes for TA4810. Both are 1:1 toughened acrylics for plastics and unprimed metals. See Permabond TA4820.

Questions on fit for your structural bonding application? Call (800) 220-1966 or email [email protected].

Additional information

Weight 1 lbs
Dimensions 6 × 6 × 6 in
Manufacturer

Component

Ratio

Must Ship Freight

Country Of Manufacture

Origin

Reviews

There are no reviews yet.

Be the first to review “Permabond TA4810 Toughened Acrylic Adhesive”

Your email address will not be published. Required fields are marked *

You may also like…