Description
The DP2X 200-10-25-01 pneumatic gun is the Sulzer Medmix DP2X 200 – 200ml Pneumatic Cartridge Gun set up for 10:1 200ml MIXPAC C-System and F-System two-part cartridges. A 10:1 cartridge meters ten parts of one component to one part of the other. It runs on compressed air through a 1/4 in NPT inlet at up to 100 psi, with an integrated regulator to adjust output force. This part number replaces the older DP 200-70-10. For full specs, the ratio change steps, and every ratio option, see the Sulzer Medmix DP2X 200 – 200ml Pneumatic Cartridge Gun page.
Part Details
| Property | Value |
|---|---|
| Medmix Part Number | DP2X 200-10-25-01 |
| Article ID | 165862 |
| Chemical Concepts SKU | CON-DP2X200-10-25-01 |
| Mix Ratio | 10:1 |
| Cartridge Size | 200ml C-System and F-System |
| Air Supply | 1/4 in NPT inlet, 100 psi (6.8 bar) maximum |
| Conversion Kit to Change Ratio | CKX 200-01-01 for 1:1 and 2:1 or CKX 200-04-01 for 4:1 |
Mixers for 10:1 Cartridges
The mixer follows the cartridge, not the gun. C-System and F-System 200ml cartridges use different mixer outlets, so match the mixer to the cartridge body.
- Xemex X2-C8-8S low-waste static mixer for C-System cartridges, including 4:1 and 10:1
- Medmix MIXPAC MFHX 08-24T static mixer for 4:1 and 10:1 F-System cartridges
Other 200ml Guns for 10:1 Cartridges
- Sulzer Medmix DM2X 200 – 200ml Manual Cartridge Gun when no air line is available
- Newborn VR200XSP variable ratio gun as a manual variable ratio option
Frequently Asked Questions
Does the DP2X 200-10-25-01 replace the DP 200-70-10?
Yes. The DP2X 200-10-25-01 replaced the older DP 200-70-10, which was discontinued years ago. Call us with your old part number and we will confirm the match.
Which cartridges fit the DP2X 200-10-25-01?
The DP2X 200-10-25-01 runs 200ml MIXPAC C-System and F-System two-part cartridges in 10:1. It does not take 400ml cartridges. If you run 250ml cartridges, call us at (800) 220-1966 before you order so we can confirm fit.
What mixer do I need for a 10:1 cartridge?
Use the Xemex X2-C8-8S low-waste static mixer for C-System cartridges or the Medmix MIXPAC MFHX 08-24T static mixer for F-System cartridges. Check the cartridge body before you order, since the two systems do not share a mixer outlet.
Can I change this gun to 1:1, 2:1, or 4:1 later?
Yes. The DP2X 200 uses interchangeable cartridge trays and plunger disks, so a conversion kit changes the ratio. This gun needs CKX 200-01-01 for 1:1 and 2:1 or CKX 200-04-01 for 4:1. See the CKX 200 conversion kits.
Is there a manual option for 200ml 10:1 cartridges?
Yes. See the Sulzer Medmix DM2X 200 – 200ml Manual Cartridge Gun for dispensing without an air line.
Questions on fit for your cartridge, ratio, or conversion kit? Call (800) 220-1966 or email [email protected].
MIXPAC is a trademark of medmix Switzerland AG.








Reviews
There are no reviews yet.